Conventional Hooter
Conventional Hooter

Conventional Hooter

Price 650 INR/ Unit

MOQ : 1 Unit

Conventional Hooter Specification

  • Suitable For
  • Fire safety applications in residential, commercial, industrial buildings
  • Alarm time
  • Continuous, until silenced/deactivated
  • Wireless
  • NO
  • Voltage
  • 24V DC (Nominal)
  • Sensor Type
  • N/A (Manual Audible Signaling Device)
  • Standby Current
  • <40mA
  • Noise Level
  • 90-110 dB at 1 meter
  • Control Distance
  • As per fire alarm loop design, typically up to 1.5 km with suitable cable and panel
  • Sensor Cable
  • 2-core fire-resistant cable recommended
  • Alarm startup time
  • <1 second after actuation
  • Working Current
  • <60mA
  • Power Supply
  • 24V DC
  • Alarm Light Color
  • Red
  • Remote Control
  • No
  • Detection Range
  • Audible within a range of up to 30 meters (approximate, depending on installation site)
  • Weight
  • Approx. 200g (may vary)
  • Humidity
  • Up to 95% RH non-condensing
  • Mounting Type
  • Surface/Wall mounted
  • Dimensions
  • Approx. 90mm diameter x 70mm depth (may vary)
  • Operating Temperature Range
  • -10°C to +55°C
  • IP Rating
  • IP 21 or better (model specific)
  • Compliance
  • IS/IEC 7240-3 or equivalent
  • Material/Enclosure
  • High-impact ABS plastic or powder-coated metal (model dependent)
  • Flash Rate (if visual indicator provided)
  • 60-90 flashes per minute
 
 

About Conventional Hooter

Exclusive range of Fire Alarm Hooter (Sounder) with Conventional type with Red metal Housings. The wall mounted medium frequency hooter designed as per industrial standard to complete the demand of Fire Alarm systems in several areas of residential, commercial & Industrial application. The Fire Alarm Hooter is a device that produces sound when Manual Call Point & Detector sense any kind of fire activity. It has dual tone sound and it is enough to make alert everyone inside the building.


FEATURES:


Compatibility with any conventional fire Alarm System

Wall mount facility

Suitable for malls, restaurant, residential etc.




Durable Design for Demanding Environments

Constructed from high-impact ABS plastic or powder-coated metal, this Conventional Hooter withstands challenging environmental conditions found in various building types. Its IP21 rating or higher (model dependent) ensures protection against dust and limited water ingress, making it suitable for indoor use under high humidity of up to 95% (non-condensing) and temperatures from -10C to +55C.


Audible and Visual Alarm Signaling

The hooter is engineered to deliver a loud, unmistakable alert with noise levels ranging from 90 to 110 dB at one meter, effectively covering an area of up to 30 meters. Select models also offer a red visual indicator with a flash rate of 60-90 times per minute, enhancing the effectiveness of alarm signaling and improving safety response times.


Easy Surface/Wall Mount Installation

Designed for flexibility, this hooter supports surface or wall mounting and comes in a compact size (approximately 90mm diameter x 70mm depth, 200g weight). Installation is streamlined using standard two-core fire-resistant cable, making it straightforward for professional installers in both retrofit and new construction scenarios.

FAQ's of Conventional Hooter:


Q: How is the Conventional Hooter typically installed?

A: The Conventional Hooter is designed for easy surface or wall mounting using the supplied brackets or fixtures. Installation should be carried out using a two-core fire-resistant cable, which ensures reliable operation as part of a fire alarm loop-typically up to 1.5 km with appropriate cabling and panel selection.

Q: What environments and applications are suitable for this hooter?

A: This hooter is ideal for a wide range of fire safety applications, including residential, commercial, and industrial buildings across India. Its durable enclosure options and compliance with IS/IEC 7240-3 standards make it suitable for installations requiring high reliability in challenging indoor environments.

Q: When does the alarm activate and how long does it sound?

A: The alarm is manually actuated as part of a fire detection system and begins sounding in less than one second after activation. It will continue to operate and emit an audible signal-plus visual flashes if equipped-until it is manually silenced or deactivated as per the fire safety process.

Q: What are the power and cabling requirements for operation?

A: The hooter operates on a nominal 24V DC power supply with a standby current below 40mA and working current below 60mA. It should be connected using a two-core fire-resistant cable to ensure both safety and compliance with fire alarm system standards.

Q: Where should the Conventional Hooter be positioned for optimal performance?

A: For maximum effectiveness, the hooter should be installed at a location central to the protected area to achieve the stated detection range of approximately 30 meters. Avoid installing in areas prone to direct water spray or excessive dust unless a higher IP-rated model is chosen.

Q: What benefits does this device provide in fire alarm systems?

A: The main benefit is rapid, unmistakable warning of fire emergencies, with both audible and (if specified) visual alarm signaling. Its durable design, compliance, and wide area coverage help ensure early alerting and safer evacuation for occupants.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Alarm System Category

2 IN 1 COMBO UNIT

2 IN 1 COMBO UNIT

Price 1100.0 INR / Unit

Minimum Order Quantity : 1 Unit

Power Supply : AC 220V / DC 12V

Alarm Density : 300 ppm (Gas), 0.3% 0.5% (Smoke)

Remote Control : Other, Available

Standby Current : 10mA

3 IN 1 COMBO UNIT

3 IN 1 COMBO UNIT

Price 1.0 INR / Unit

Minimum Order Quantity : 1 Unit

Power Supply : AC 110V220V or DC 12V

Alarm Density : 0.1% ~ 0.3% db/m (for smoke detection)

Remote Control : Other, Yes (included)

Standby Current : 10mA

Conventional MCP

Conventional MCP

Price 700 INR / Unit

Minimum Order Quantity : 1 Unit

Power Supply : 24V DC

Alarm Density : 0.10.3%/ft

Remote Control : Other, Available

Standby Current : 10mA

Fire Alarm Talk Back System

Fire Alarm Talk Back System

Power Supply : AC 220V / 50Hz

Alarm Density : 0.10.3 dB/m

Remote Control : Yes

Standby Current : <15mA



Back to top