Fire Alarm Talk Back System
Fire Alarm Talk Back System

Fire Alarm Talk Back System

Fire Alarm Talk Back System Specification

  • Working Current
  • <100mA
  • Sensor Type
  • Smoke/Heat Sensor Compatible
  • Sensor Cable
  • Standard Fire Rated Cable
  • Suitable For
  • Commercial Buildings, Industrial, Hospitals, Institutions
  • Voltage
  • 12V DC Operating
  • Alarm time
  • Continuous till Reset
  • Sensor Life
  • > 5 years
  • Sensitivity
  • High (Adjustable)
  • Wireless
  • Optional
  • Control Distance
  • Up to 500 meters
  • Wireless Distance
  • Up to 100 meters
  • Noise Level
  • >90 dB
  • Standby Current
  • <15mA
  • Alarm Density
  • 0.1-0.3 dB/m
  • Alarm startup time
  • < 3 seconds
  • Power Supply
  • AC 220V / 50Hz
  • Alarm Light Color
  • Red
  • Remote Control
  • Yes
  • Detection Range
  • 100-200 meters
  • Operating Temperature
  • -10°C to +55°C
  • Reset Method
  • Manual/Automatic Reset
  • Control Panel
  • Microprocessor Based
  • Zones Supported
  • Expandable (up to 32 zones or as per model)
  • Mounting Accessories
  • Provided with Unit
  • Display
  • LED Indication
  • Enclosure Material
  • Powder Coated Metal Cabinet
  • Battery Backup
  • 12V Rechargeable Inbuilt (optional)
  • Communication Module
  • Two-way Talkback Intercom
  • Installation
  • Wall Mount
 
 

About Fire Alarm Talk Back System

Fostered with immense years of industry experience and market understanding, we are offering a wide gamut of Talk Back System with Fire Alarm. The provided alarm is manufactured using optimum quality raw material and ultra modern technology by our skilled team of professionals as per the industry norms. This alarm is highly demanded in commercial and residential places. Furthermore, this Talk Back System with Fire Alarm is made available to the clients at reasonable prices.

Features:

  • Talk Back Unit as per IS: 2189.

  • Simplex type talk back unit

  • Prevention for unauthorized uses

  • Simple operation



Advanced Two-Way Communication for Emergency Response

The integrated talkback intercom enables occupants to communicate directly with the control panel, ensuring swift and coordinated action during fire emergencies. Remote control access and clear LED indications further improve operational response, helping responders direct evacuations and manage situations more efficiently.


Expandable and Adaptable Zone Coverage

Suitable for various environments, the system supports up to 32 zones (or as per model specifications) and can be tailored to building requirements. Its compatibility with both smoke and heat sensors offers robust detection across extensive areas, and adjustable sensitivity ensures accurate alarm triggers.


Reliable and Safe System Design

Constructed from powder-coated metal and supporting wall mounting, the unit offers longevity and security. The optional rechargeable inbuilt battery and standard fire-rated cable provide fail-safe operation, while continuous alarms and manual/automatic reset options ensure hazards are promptly addressed without delay.

FAQs of Fire Alarm Talk Back System:


Q: How is the Fire Alarm Talk Back System installed in a building?

A: The system is designed for wall-mounted installation using provided mounting accessories, ensuring a secure and accessible placement. Its compact, powder-coated metal cabinet supports easy integration into commercial, industrial, or institutional environments.

Q: What benefits does the two-way talkback intercom offer during an emergency?

A: The two-way intercom allows real-time communication between occupants and emergency personnel. This feature ensures quick dissemination of instructions during fire events, enhancing safety and coordination for faster evacuations.

Q: When should the fire alarm system be reset, and how is it done?

A: The system supports both manual and automatic reset methods. Typically, after confirming the threat is eliminated, operators can reset the system to restore normal operation, either by pressing the panel button or following the programmed reset protocol.

Q: Where can this Fire Alarm Talk Back System be effectively used?

A: Ideal for commercial buildings, hospitals, industrial complexes, and large institutions, the systems expandable zone coverage and reliable communication make it suitable for spaces that require swift emergency response and adaptable fire detection.

Q: What is the process for expanding zones or adding sensors?

A: The control panel, being microprocessor-based, supports zone expansion. Additional zones and compatible smoke/heat sensors may be integrated as per the buildings requirements, following the manufacturers guidelines for wiring and configuration.

Q: How does the wireless option enhance system usability?

A: Wireless connectivity allows flexible installation in areas where cabling is difficult, supporting detection range up to 100 meters. This option simplifies integration in complex building layouts, improving detection coverage without extensive wiring.

Q: What are the key advantages of battery backup and remote control features?

A: The optional 12V rechargeable battery ensures uninterrupted operation during power failures, and remote control functionality allows authorized personnel to monitor or trigger system actions from up to 500 meters, increasing overall reliability and control.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Alarm System Category

2 IN 1 COMBO UNIT

2 IN 1 COMBO UNIT

Price 1100.0 INR / Unit

Minimum Order Quantity : 1 Unit

Power Supply : AC 220V / DC 12V

Control Distance : Up to 100 meters

Noise Level : >85dB

Standby Current : 10mA

3 IN 1 COMBO UNIT

3 IN 1 COMBO UNIT

Price 1.0 INR / Unit

Minimum Order Quantity : 1 Unit

Power Supply : AC 110V220V or DC 12V

Control Distance : Up to 30 meters

Noise Level : 110 dB

Standby Current : 10mA

Conventional MCP

Conventional MCP

Price 700 INR / Unit

Minimum Order Quantity : 1 Unit

Power Supply : 24V DC

Control Distance : Up to 1 Km

Noise Level : 50dB

Standby Current : 10mA

Conventional Hooter

Conventional Hooter

Price 650 INR / Unit

Minimum Order Quantity : 1 Unit

Power Supply : 24V DC

Control Distance : As per fire alarm loop design, typically up to 1.5 km with suitable cable and panel

Noise Level : 90110 dB at 1 meter

Standby Current : <40mA



Back to top